  • Submersible PVC Flat Cable - 3Core as per IS 694
Conductor PVC Insulation PVC Sheath
Nominal Area in Nos. & Dia. of wire Nominal Thickness Core Dia Nominal Thickness Approx. Overall Dimensions Conductor [email protected] 20° C (Max.) Current Rating at 40°C
mm (Nom.) Thickness Width
Sq. mm. Nos./mm mm mm mm mm mm Ohm/km Amps.
1.5 22/0.30 0.60 2.90 0.90 5.20 11.30 12.10 16
2.5 36/0.30 0.70 3.50 1 6.20 13.30 7.41 22
4 56/0.30 0.80 4.20 1 7 15.60 4.95 29
6 84/0.30 0.80 5.20 1.40 8 18.50 3.30 37
10 80/0.40 1.00 6.50 1.60 9.30 22.50 1.91 51
16 126/0.40 1.00 8.00 1.80 11.60 27.50 1.21 68
25 196/0.40 1.20 9.80 2.20 14.20 35.00 0.780 86
35 276/0.40 1.20 10.90 2.20 15.30 37.00 0.554 110
50 396/0.40 1.40 13.20 2.40 18.00 44.00 0.386 145

Note:
Insulation thickness, Sheath thickness and Overall Dimensions given in this table are nominal values. The strand diameter is nominal.However, Construction of the conductor is designed to the requirement of conductor resistance as per IS 8130 :1984.