Call Us Now : +022-25792011

Products

 
 
Control Cables

These cables are used for low volatge Electrical power station, indoor or Outdoor,all kinds of Industrial Applications.

Standards as per IS - 1554 (Part-1)

Max. Conductor D.C. Resisitance at 200C conductor size 1.50 sq.mm - 12.1 W/km (Bare) and 12.2 W /km (Tinned copper) 2.50 sqmm - 7.41 W/km (Bare) and 7.56 W/km (Tinned Copper)
 

No.of Core & C.S. Area

Thick of PVC Insul

Thick of Inner

Thick of Outer

Appx. O.D.

Appx. Net Wt of

Current Rating

Sheath

Sheath

Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

No. x “sq. mm”

Nom. “mm”

Min. “mm”

“mm” (Nom)

“mm”

“kg/km”

Direct in Ground “Amps”

In Air/ Duct Amps”

 

 

 

 

 

 

 

 

2 x 1.50

0.80

0.30

1.80

11.8

185

23

20

3 x 1.50

0.80

0.30

1.80

12.3

190

21

17

4 x 1.50

0.80

0.30

1.80

13.2

225

21

17

5 x 1.50

0.80

0.30

1.80

14.1

260

16

14

6 x 1.50

0.80

0.30

1.80

15.1

295

15

13

7 x 1.50

0.80

0.30

1.80

15.1

315

14

13

10 x 1.50

0.80

0.30

1.80

18.4

425

13

11

12 x 1.50

0.80

0.30

1.80

18.9

480

12

10

14 x 1.50

0.80

0.30

1.80

19.8

535

11

10

16 x 1.50

0.80

0.30

1.80

20.7

595

11

9

19 x 1.50

0.80

0.30

2.00

22.5

720

10

9

24 x 1.50

0.80

0.30

2.00

25.8

880

9

8

27 x 1.50

0.80

0.30

2.00

26.3

960

9

8

30 x 1.50

0.80

0.30

2.00

27.2

1080

9

7

37 x 1.50

0.80

0.30

2.00

29.1

1230

8

7

2 x 2.50

0.90

0.30

1.80

13.0

230

32

27

3 x 2.50

0.90

0.30

1.80

13.6

240

27

24

4 x 2.50

0.90

0.30

1.80

14.6

290

27

24

5 x 2.50

0.90

0.30

1.80

15.7

335

23

19

6 x 2.50

0.90

0.30

1.80

16.9

385

21

18

7 x 2.50

0.90

0.30

1.80

16.9

420

20

17

10 x 2.50

0.90

0.30

1.80

20.8

570

18

15

12 x 2.50

0.90

0.30

2.00

22.2

690

17

14

14 x 2.50

0.90

0.30

2.00

23.2

775

16

13

16 x 2.50

0.90

0.30

2.00

24.3

860

15

13

19 x 2.50

0.90

0.30

2.00

25.5

985

14

12

24 x 2.50

0.90

0.30

2.00

29.4

1215

13

11

27 x 2.50

0.90

0.30

2.00

30.0

1330

12

10

30 x 2.50

0.90

0.30

2.00

31.0

1450

12

10

37 x 2.50

0.90

0.40

2.00

34.1

1790

11

9

 

 

 

 

 

 

 

 

 

 

 

 

 

Thick of PVC

 

Appx. Net Wt

 

Thick of

Appx.

Appx.

Direct in

 

 

 

 

 

Appx. O.D.

Wire Dia

PVC Outer

Net Wt

In Air/ Duct

No. x “sq. mm”

Nom. “mm”

Min. “mm”

Strip Size

Outer Sheath

of Cable “kg/

O.D.

Ground

 

 

 

 

“mm” min

“mm”

km”

“mm”

Sheath

“mm”

of Cable

“Amps”

“Amps”

 

 

 

 

 

 

“mm” min

“kg/km”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 x 1.50

0.80

0.30

-

-

-

-

1.40

1.24

13.6

415

23

20

3 x 1.50

0.80

0.30

-

-

-

-

1.40

1.24

14.1

430

21

17

4 x 1.50

0.80

0.30

-

-

-

-

1.40

1.24

15.0

490

21

17

5 x 1.50

0.80

0.30

-

-

-

-

1.40

1.24

15.9

545

16

14

6 x 1.50

0.80

0.30

-

-

-

-

1.40

1.24

16.9

605

15

13

7 x 1.50

0.80

0.30

-

-

-

-

1.40

1.24

16.9

630

14

13

10 x 1.50

0.80

0.30

-

-

-

-

1.40

1.40

20.6

835

13

11

12 x 1.50

0.80

0.30

4 x 0.80

1.24

19.5

760

1.60

1.40

21.5

950

12

10

14 x 1.50

0.80

0.30

4 x 0.80

1.40

20.8

830

1.60

1.40

22.4

1040

11

10

16 x 1.50

0.80

0.30

4 x 0.80

1.40

21.7

920

1.60

1.40

23.3

1130

11

9

19 x 1.50

0.80

0.30

4 x 0.80

1.40

23.1

1040

1.60

1.40

24.7

1265

10

9

24 x 1.50

0.80

0.30

4 x 0.80

1.40

26.4

1250

1.60

1.40

28.0

1510

9

8

27 x 1.50

0.80

0.30

4 x 0.80

1.40

26.9

1355

1.60

1.40

28.5

1610

9

8

30 x 1.50

0.80

0.30

4 x 0.80

1.40

27.8

1430

1.60

1.40

29.4

1700

9

7

37 x 1.50

0.80

0.30

4 x 0.80

1.40

29.7

1670

1.60

1.40

31.3

1960

8

7

2 x 2.50

0.90

0.30

-

-

-

-

1.40

1.24

14.8

500

32

27

3 x 2.50

0.90

0.30

-

-

-

-

1.40

1.24

15.4

520

27

24

4 x 2.50

0.90

0.30

-

-

-

-

1.40

1.24

16.4

590

27

24

5 x 2.50

0.90

0.30

-

-

-

-

1.40

1.24

17.5

660

23

19

6 x 2.50

0.90

0.30

-

-

-

-

1.40

1.24

18.7

745

21

18

7 x 2.50

0.90

0.30

-

-

-

-

1.40

1.24

18.7

780

20

17

10 x 2.50

0.90

0.30

4 x 0.80

1.40

21.8

900

1.60

1.40

23.4

1110

18

15

12 x 2.50

0.90

0.30

4 x 0.80

1.40

22.8

1020

1.60

1.40

24.4

1240

17

14

14 x 2.50

0.90

0.30

4 x 0.80

1.40

23.8

1130

1.60

1.40

25.4

1340

16

13

16 x 2.50

0.90

0.30

4 x 0.80

1.40

24.9

1210

1.60

1.40

26.5

1455

15

13

19 x 2.50

0.90

0.30

4 x 0.80

1.40

26.1

1355

1.60

1.40

27.7

1605

14

12

24 x 2.50

0.90

0.30

4 x 0.80

1.40

30.0

1655

1.60

1.56

32.0

1970

13

11

27 x 2.50

0.90

0.30

4 x 0.80

1.40

30.6

1770

1.60

1.56

32.6

2100

12

10

30 x 2.50

0.90

0.30

4 x 0.80

1.56

32.0

1940

1.60

1.56

33.6

2250

12

10

37 x 2.50

0.90

0.40

4 x 0.80

1.56

34.7

2300

2.00

1.56

37.1

2900

11

9

 

 

 

 

 

 

 

 

 

 

 

 

 


 
 
 
 
Follow us on  

Home

Contact  Details  
     
  Facebook
  Twitter
  Linked In
 
   
Miracle Cables (India) Pvt. Ltd.
1203, Dhamji Shamji Bussiness Galeria, L.B.S Marg, Near Huma Talkies ,Kanjur Marg West, Mumbai – 400078
+91 022-25792011
[email protected]



Copyright © 2015 - Miracle Cables Pvt. Ltd.

 

Website designed by - OVERTURES InfoTech